Download drivers for EnGenius 802.11n Wireless USB Adapter Wi-Fi devices (Windows 10 x86), or install DriverPack Solution software for automatic driver download and update. After the download WindowsSupport folder containing drivers will appear in the selected location. Add driver to the system Run WindowsSupport BootCamp Drivers Broadcom BroadcomBluetooth64.exe (probably similar procedure will work for WiFi, so you could also run BroadcomWirelessUDMx64.exe to add drivers to the system) Install the driver 1. Download the latest drivers, firmware, and software for your HP LaserJet 2420n Printer.This is HP’s official website that will help automatically detect and download the correct drivers free of cost for your HP Computing and Printing products for Windows and Mac operating system. Seneca is definitely helping out with student engagement. One of my students was just saying today they are glad you guys came up with this. They find it helpful and engaging. Planex Network & Wireless Cards Driver Download for windows. Keep in touch while hiking, climbing, skydiving, boating, or doing whatever gets you outside. Sena’s line of action sports Bluetooth devices includes our headsets, cameras, and adapters - which offer exceptional video and audio recording capabilities, helping to enhance the lives of speed demons and action-seekers everywhere.
Literature and Links
| How to Order
| ||
Model | Input/Output | Features | Product |
---|---|---|---|
DC to DC Isolated Signal ConditionerField ConfigurableK109UI $169 *stock item*Open Datasheet Download Datasheet Open Installation Manual Download Installation Manual Click to see ALL Seneca products |
| K109UI | |
DC to DC Isolated Transmitter |
| K109S | |
Universal Input to 4-20 mA Loop Powered TransmitterField ProgrammableK121 $149 *stock item*Open Datasheet Download Datasheet Open Installation Manual Download Installation Manual Click to see ALL Seneca products |
| K121 | |
Thermocouple to DC Isolated TransmitterField ConfigurableK109TC $169 *stock item*Open Datasheet Download Datasheet Open Installation Manual Download Installation Manual Click to see ALL Seneca products |
| K109TC | |
100 Ω RTD to DC Isolated TransmitterField ConfigurableK109PT $169 *stock item*Open Datasheet Download Datasheet Open Installation Manual Download Installation Manual Click to see ALL Seneca products |
| K109PT | |
RS-485 to RS-485 or |
| Regulated Power Distribution Input: 19.2 to 30 VDC Output: 19.2 to 30 VDC | K-SUPPLY K-BUS |
Strain Gauge/Load Cell/Bridge Input / RS485 Modbus and Analog OutputZ-SG $250 *stock item*Open Z-SG datasheet Download Z-SG datasheet Open Z-SG installation Download Z-SG installation Open Z-SG user manual Download Z-SG usr manual Open Z-SG calibration procedure Download Z-SG calibration procedure | Field Configurable Input Input: One input channel connection for up to 4 (350 Ω) or 8 (1000 Ω) strain gauge load cells 4 or 6 wire Excitation supply Sensitivity: 1 to 64 mV/V Switch I/O for either tare or alarm Field Configurable Output Output: 4-20 mA, 0-20 mA 0-5 V, 0-10 V Modbus RTU with backplane connector system Open Z-SG application note Download Z-SG application note Download Z-SG DWG CAD file Download Z-SG 3D STP CAD file Download Z-series LabView drivers |
| Z-SG |
Strain Gauge/Load Cell/Bridge Input | Field Configurable Input Input: One input channel connection for up to 4 (350 Ω) or 8 (1000 Ω) strain gauge load cells 4 or 6 wire Excitation supply Sensitivity: 1 to 64 mV/V Switch I/O for either tare or alarm Field Configurable Output Output: 4-20 mA, 0-20 mA 0-5 V, 0-10 V Modbus RTU requires backplane connector system Configure with EASY SETUP software and standard micro-USB cable 0.01% FS accuracy class 24 bit analog-digital conversion Upgradeable firmware Settable sampling rate Alarm with programmable hysteresis Configurable resolution Settable floating-point value Stabilized measurement with noise filter Download EASY SETUP software Download Z-series LabView drivers Download Z-SG2 DWG CAD file Download Z-SG2 3D STP CAD file |
| Z-SG2 |
Load Cell, Strain Gauge, Bridge | Input Up to 4 strain gauges Output Summed signal from up to 4 strain gauges |
| SG-EQ4 SG-EQ4-BOXPG7 |
Z-Series Backplane ConnectorZ-PC-DINAL1-35 $40Open Z-PC-DINAL datasheet Download Z-PC-DINAL datasheet Open Z-PC-DIN overview Download Z-PC-DIN overview | Head terminal + 1 slot For one 17.5mm or one 35mm wide Z-PC module Connect power Connect Modbus Required for Modbus connection | DIN rail mount with screw terminals, 1 slot Connect one 17.5 or 35mm Z-PC series module | Z-PC-DINAL1-35 |
Z-Series Backplane ConnectorZ-PC-DINAL2-17.5 $47.50 *stock item*Open Z-PC-Z-PC-DINAL datasheet Download Z-PC-DINAL datasheet Open Z-PC-DIN overview Download Z-PC-DIN overview | Head terminal + 2 slots For one or two 17.5mm wide Z-PC modules Connect power Connect Modbus Required for Modbus connection | DIN rail mount with screw terminals, 2 slots Connect one or two 17.5mm Z-PC series modules | Z-PC-DINAL2-17.5 |
Z-Series Backplane ExtenderZ-PC-DIN2-17.5 $30 *stock item*Open Z-PC-DIN2 datasheet Download Z-PC-DIN2 datasheet Open Z-PC-DIN overview Download Z-PC-DIN overview | 2 slot extension terminal For one or two 17.5mm wide Z-PC modules Connect power Connect Modbus Required for Modbus connection | DIN rail mount with 2 slots Add one or two 17.5mm Z-PC series modules | Z-PC-DIN2-17.5 |
24 VDC Loop Power SupplyZ-SUPPLY $199 *stock item*Open Datasheet Download Datasheet Open Installation Manual Download Installation Manual Click to see ALL Seneca products Download CAD Drawing | Input Power 110 VAC to 230 VAC, 47-63 Hz, 0.7 A, or 110 VDC to 315 VDC, 0.7 A Output 24 VDC ±2%, 1.5 A max. |
| Z-SUPPLY |
Z110 Loop Powered Isolators | Input Z110S: One 4-20 mA loop Z110D: Two 4-20 mA loops Output Z110S: One isolated 4-20 mA loop Z110D: Two isolated 4-20 mA loops |
| Z110S Z110D |
RS232/USB, TTL/USB, RS485/USB Isolated Serial ConverterSeneca S117P-1 $260 *stock item*Open S117P-1 datasheet Download S117P-1 datasheet Open S117P-1 installation Download S117P-1 installation S117P-1 SoftwareDownload S117P-1 Software | Programming kit for T120 T121 Z-SG | Includes Converter box Software mini CD (or download latest) Adapter cable | S117P1 |
4 Digit 4-20 mA Loop Powered DisplayField RangeableS315 $139 *stock item* |
| S315 | |
USB - UART TTL ConverterEASY-USB $109 *stock item*Open Datasheet Download Datasheet Open Installation Manual Download Installation Manual EASY-USB Software Link | Programming kitK121 K121 | Includes Converter Software mini CD (or download latest) Adapter cable (std USB cable not included) | EASY-USB |
Head-Mount RTD Transmitter, Non-IsolatedField ProgrammableFits DIN Form B Heads T120 $89 *stock item*Open Datasheet Download Datasheet Open Installation Manual Download Installation Manual Click to see ALL Seneca products |
| T120 | |
Head-Mount Universal Transmitter, IsolatedField ProgrammableFits DIN Form B Heads T121 $159 *stock item*Open Datasheet Download Datasheet Open Installation Manual Download Installation Manual Click to see ALL Seneca products |
| T121 | |
AC Current Transmitter Loop PoweredField Selectabe Ranges Open Current Sensor Overview Download Current Sensor Overview T201 to 40A $99 *stock item*Open Installation ManualDownload Installation Manual | Input T201 5, 10, 15, 20, 25, 30, 35, 40 Amps AC Output 4-20 mA Power 5-28 VDC current loop |
| T201 |
DC Current Transmitters Loop PoweredField Selectabe Ranges Open Current Sensor Overview Download Current Sensor Overview T201DC to 40A $159 *stock item*Open T201DC Installation ManualDownload T201DC Installation Manual T201DC100 to 100A $219Open T201DC100 Installation ManualDownload T201DC100 Installation Manual | Input T201DC 5, 10, 20, 40, ±5, ±10, –5-20, –10-40 ADC Input T201DC100 10, 25, 50, 100, ±5, ±10, –5-20, –10-40 ADC Output 4-20 mA Power 5-28 VDC current loop |
| T201DC 40 Amp DC T201DC 100 Amp DC |
AC/DC Hall Effect Current Transmitters 0-10V OutputField Selectable Ranges Open Current Sensor Overview Download Current Sensor Overview T201DCH 50A $109 *stock item*Open T201DCH Installation ManualDownload T201DCH Installation Manual T201DCH100 100A $149Open T201DCH100 Installation ManualDownload T201DCH100 Installation Manual T201DCH300 300A $159 *stock item*Open T201DCH300 Installation ManualDownload T201DCH300 Installation Manual | Input T201DCH 25, 50 ADC/AAC Input T201DCH100 50, 100 ADC/AAC, ±50, ±100 ADC Input T201DCH300 150, 300 ADC/AAC, ±150, ±300 ADC Output 0-10 VDC Powered by 10-28 VDC |
| T201DCH 50 Amp T201DCH 100, 300 Amp |
AC/DC Hall Effect Current Transmitters Loop PoweredField Selectable Ranges Open Current Sensor Overview Download Current Sensor Overview T201DCH50-LP 50A $109Open T201DCH50-LP Installation ManualDownload T201DCH50-LP Installation Manual T201DCH100-LP 100A $149Open T201DCH100-LP Installation ManualDownload T201DCH100-LP Installation Manual T201DCH300-LP 300A $159Open T201DCH300-LP Installation ManualDownload T201DCH300-LP Installation Manual | Input T201DCH50-LP 50 ADC/AAC, ±50 ADC Input T201DCH100-LP 50, 100 ADC/AAC, ±50, ±100 ADC Input T201DCH300-LP 150, 300 ADC/AAC, ±150, ±300 ADC Output 4-20 mA Power 9-28 VDC current loop |
| T201DCH 50 Amp T201DCH 100, 300 Amp |
AC to DC Isolated Current MeasurementField Configurable Z201-H $179Module power: 85-265 VAC/VDCZ201 $179Module power: 19-40 VDC, 19-28 VACOpen Datasheet Download Datasheet Open Z201-H manual Download Z201-H manual Open Z201 manual Download Z201 manual | Field selectable input ranges 0-5 Amps AC 0-10 Amps AC Selectable via wiring terminal Field selectable output ranges 0-1 V, 0-5 V, 0-10 V, 2-10 V 0-20 mA, 4-20 mA sink or source |
| Seneca Z201-H and Z201 |